Lane 1: Building Intelligence

Energy Retrofits &
Analytics

Proven physical retrofits — energy valves, VFD installations, Delta-T correction, chiller fine-tuning — combined with IPMVP-compliant measurement and verification so you can see and prove every dirham of savings.

10–30%
Energy Reduction
IPMVP
Verified Savings
18–24mo
Payback Period
The Problem

Where Energy Is Being Lost

Chilled water systems lose efficiency through a handful of well-understood failure modes. The challenge isn't identifying them — it's having the measurement infrastructure to prove the savings once they're fixed.

Low Delta-T Syndrome

Chilled water returns at near-supply temperature. Pumps circulate excess flow while delivering no additional cooling. Secondary pumps run hard to compensate for a hydraulic problem, not a capacity one.

Our Fix

Delta-T correction programme — PICV valves, hydraulic balancing, bypass correction.

No Sub-Metering

A single utility meter hides zone and system-level waste. You can't target improvements without knowing which circuits consume what, and you can't prove savings without circuit-level data.

Our Fix

Energy valve installation with real-time flow and energy data per circuit, integrated to BMS.

Oversized Fixed-Speed Equipment

Pumps and fans designed for peak load run at 100% regardless of actual demand. Fixed-speed operation at part load is energetically wasteful — a 20% speed reduction cuts energy consumption by nearly 50%.

Our Fix

VFD retrofit matched to actual demand profile with differential pressure reset control.

Can't Prove Savings

Retrofit ROI gets challenged by finance teams without independent verification. Good work gets written off without a credible baseline and ongoing M&V methodology that finance teams accept.

Our Fix

IPMVP Option B baseline with ongoing M&V reporting and weather normalisation.

Capabilities

Our Technical
Approach

Physical retrofits engineered for the Gulf climate, verified with IPMVP-compliant measurement and verification. Every saving is documented and defensible.

Hardware Partners
Belimo Energy Valves
Variable Frequency Drives (VFDs)
IPMVP Option B M&V
01
Delta-T Correction Programme
Identify and correct low Delta-T syndrome: install pressure-independent control valves (PICV), rebalance secondary circuits, correct bypass valve sizing. Restore design Delta-T across the chilled water distribution system.
PICV Installation Hydraulic Balancing Bypass Correction
02
Energy Valve Installation
Supply and install Belimo energy valves for chilled and hot water circuits. Commissioning and BMS integration included. Real-time flow and energy data per circuit, logged and accessible via dashboard.
Belimo EV Circuit Metering
03
Chiller Plant Fine-Tuning
Optimise chiller sequencing, set chilled water supply temperature reset schedules, correct condenser water setpoints and cooling tower approach temperature. Squeeze maximum COP from existing plant without hardware replacement.
Chiller Sequencing CHWS Reset CT Approach Temp
04
VFD Retrofit & Variable Flow
Retrofit constant-speed pumps and AHU fans with variable frequency drives. Implement differential pressure reset to match actual system demand. Savings verified against pre-retrofit baseline with calibrated power metering.
Pump VFD Fan VFD DP Reset
05
IPMVP Measurement & Verification
Establish ASHRAE/IPMVP-compliant energy baselines with weather normalisation. Monthly M&V reporting with verified savings and payback tracking. Reports formatted for finance team review and regulatory submissions.
IPMVP Option B Weather Normalised Monthly Reports
10–30%
Energy Reduction
IPMVP
Verified
18–24mo
Payback
Belimo
Hardware Partner
Proof of Work

See how it performs in the real world.

IPMVP-verified energy savings, payback timelines, and retrofit case studies across our portfolio.

View Outcomes

Ready to prove your energy savings?

Book an energy assessment. We'll establish your baseline, identify retrofit opportunities, and price an IPMVP-verified programme.